Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Vasc Access ; 23(4): 567-573, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33769118

RESUMO

OBJECTIVE: Safety and efficacy of ECG-guided PICC insertion using a new silicon catheter with a conductive tip was evaluated in daily practice. METHODS: A retrospective study was conducted on 1659 patients who accepted successful tip-conductive PICC placement and clinically followed-up until the catheter removal between January 2018 and April 2019. Baseline of patient characteristics, catheter placement characteristics, date of dressing changes as well as records of catheter-related complications were extracted from a special designed mobile APP. RESULTS: The first-attempt success (success of placing catheter tip to the ideal position by primary indwelling operation) rate of PICC placement was 99.3%. The average duration of PICC placement was 128.7 ± 39.5 days and 1535 patients (92.5%) reached the therapy end-point without any complications and removed the catheter normally. The cumulative rates of total complications were 7.5%, including exit site infection (2.5%), phlebitis (0.9%), DVT (1.0%), catheter malposition (1.1%), catheter breakage (0.1%), and liquid extravasation (1.8%). In multivariable logistic regression analyses, hyperlipidemia, diabetes mellitus, lung cancer, stomach cancer, and lymphoma were significantly associated with increased risk of complications, as the independent risk factors. CONCLUSIONS: This retrospective clinical study demonstrates that ECG-guided insertion of a new tip-conductive PICC is associated with a high rate of first-attempt success and low rate of catheter related complications.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Eletrocardiografia , Humanos , Estudos Retrospectivos , Silício
2.
Circ J ; 86(4): 642-650, 2022 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-34759131

RESUMO

BACKGROUND: Application of drug-coated balloons (DCBs) is popular for the treatment of percutaneous coronary intervention (PCI). A new DCB has been designed as ultrasound-controlled paclitaxel releasing. This study was conducted to determine whether a DCB-only strategy has a similar safety profile and equal angiographic and clinical outcomes to DES implantation in primary ST-elevation myocardial infarction (STEMI) patients, as well as determine the efficiency and safety of this new DCB.Methods and Results:Overall, 184 pretreated STEMI patients were randomized into DCB and DES groups with a 1:1 allocation. The main study end-point was late lumen loss (LLL) during the 9 months after PCI. Late lumen loss was reported to be 0.24±0.39 mm in the DCB group and 0.31±0.38 mm in the DES group (P=0.215). Diameter stenosis was 28.27±15.35% in the DCB group and 25.73±15.41% in the DES group (P=0.312). Major adverse cardiovascular events (MACEs) were reported in 3 patients (3.4%) in the DCB group and 4 patients (4.7%) in the DES group (P=0.718). TLR and TVR in the DCB group was 2.3%, 3.4% and 2.4%, 3.5% in the DES group (P=1.000), respectively. No cardiac death and stent thrombosis (ST) was found in the DCB group at 12 months clinical follow up. CONCLUSIONS: The DCB-only strategy showed good angiographic and clinical outcomes in the 9- and 12-month follow-up periods, respectively. The VasoguardTM DCB is safe and feasible to treat STEMI patients.


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Angioplastia Coronária com Balão/métodos , Humanos , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento
3.
BMC Cardiovasc Disord ; 21(1): 518, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34702176

RESUMO

BACKGROUND: Atherosclerosis is the main cause of carotid artery stenosis (CAS) which mostly occurs in the elderly. In this paper, the expression level of miR-375-3p in asymptomatic CAS patients and its diagnostic value for asymptomatic CAS were investigated, and the effects of miR-375-3p on the cell proliferation and migration of vascular smooth muscle cells (VSMCs) was further explored. METHODS: 98 healthy subjects and 101 asymptomatic CAS patients were participated in this study. qRT-PCR was used to measure the expression level of serum miR-375-3p, and the ROC curve was established to evaluate the predictive value of miR-375-3p for asymptomatic CAS. After transfection with miR-375-3p mimic or inhibitor in vitro, cell proliferation and migration were detected by CCK-8 assay, colony formation assay, and Transwell assay, respectively. The levels of TNF-α, IL-1ß, IL-6 were detected by ELISA. Western blot was used to detect the protein expression of XIAP. Finally, luciferase reporter gene assay was applied to assess the interaction of miR-375-3p with target genes. RESULTS: The expression level of serum miR-375-3p in asymptomatic CAS patients was significantly higher than that in healthy controls, and the AUC value of ROC curve was 0.888. The sensitivity and specificity were 80.2 and 86.7%, respectively, indicating that miR-375-3p had high diagnostic value for asymptomatic CAS. In vitro cell experiments showed that up-regulation of miR-375-3p significantly promoted the proliferation and migration of VSMCs, and also promoted the generation of inflammatory factors and phenotypic transformation of VSMCs. Luciferase reporter gene assay confirmed that XIAP was a target gene of miR-375-3p and was negatively regulated by miR-375-3p. CONCLUSIONS: In this study, miR-375-3p may have a clinical diagnostic value for asymptomatic CAS patients which need further validation. Increased miR-375-3p levels in CAS may be associated with increased proliferation and migration of VSMCs via downregulation of the apoptosis inducing gene XIAP.


Assuntos
Estenose das Carótidas/genética , Proliferação de Células/genética , MicroRNAs/fisiologia , Músculo Liso Vascular/citologia , Miócitos de Músculo Liso/fisiologia , Idoso , Biomarcadores/sangue , Estenose das Carótidas/sangue , Estenose das Carótidas/fisiopatologia , Estudos de Casos e Controles , Feminino , Humanos , Masculino , MicroRNAs/sangue , MicroRNAs/metabolismo , Pessoa de Meia-Idade , Músculo Liso Vascular/fisiologia , Curva ROC
4.
J Korean Neurosurg Soc ; 64(2): 297-308, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33626856

RESUMO

OBJECTIVE: Shunt infection is a common complication while treating hydrocephalus. The antibiotic-impregnated shunt catheter (AISC) was designed to reduce shunt infection rate. A meta-analysis was conducted to study the effectiveness of AISCs in reduction of shunt infection in terms of age, follow-up time and high-risk patient population. METHODS: This study reviewed literature from three databases including PubMed, EMBASE, and Cochrane Library (from 2000 to March 2019). Clinical studies from controlled trials for shunt operation were included in this analysis. A subgroup analysis was performed based on the patient's age, follow-up time and high-risk population. The fixed effect in RevMan 5.3 software (Cochrane Collaboration) was used for this meta-analysis. RESULTS: This study included 19 controlled clinical trials including 10105 operations. The analysis demonstrated that AISC could reduce the infection rate in shunt surgery compared to standard shunt catheter (non-AISC) from 8.13% to 4.09% (odds ratio [OR], 0.48; 95% confidence interval [CI], 0.40-0.58; p=0.01; I2=46%). Subgroup analysis of different age groups showed that AISC had significant antimicrobial effects in all three groups (adult, infant, and adolescent). Follow-up time analysis showed that AISC was effective in preventing early shunt infections (within 6 months after implant). AISC is more effective in high-risk population (OR, 0.24; 95% CI, 0.14-0.40; p=0.60; I2=0%) than in general patient population. CONCLUSION: The results of meta-analysis indicated that AISC is an effective method for reducing shunt infection. We recommend that AISC should be considered for use in infants and high-risk groups. For adult patients, the choice for AISC could be determined based on the treatment cost.

5.
DNA Cell Biol ; 40(2): 157-171, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33439750

RESUMO

Effective and efficient efferocytosis of dead cells and associated cellular debris are critical to tissue homeostasis and healing of injured tissues. This important task was previously thought to be restricted to professional phagocytes (PPs). However, accumulating evidence has revealed another type of phagocyte, the amateur phagocyte (AP), which can also participate in efferocytosis. APs are non-myeloid progenitor/nonimmune cells that include differentiated cells (e.g., epithelial cells, fibroblasts, and endothelial cells [ECs]) and stem cells (e.g., neuronal progenitor cells and mesenchymal cells) and can be found throughout the human body. Studies have shown that APs have two prominent roles: identifying and removing dead cells presumably before PPs reach the site of injury and assisting PPs in the removal of cell corpses and the resolution of inflamed tissue. With respect to the engulfment and degradation of dead cells, APs are slower and less efficient than PPs. However, APs are fundamental to preventing the spread of inflammation over a large area. In this review, we present the diversity and characteristics of healthy and non-neoplastic APs in mammals. We also propose a hypothetical mechanism of the efferocytosis of immunoglobulin G (IgG)-opsonized myelin debris by ECs (APs). Furthermore, the ingestion and clearance of dead cells can induce proinflammatory or anti-inflammatory cytokine production, endothelial activation, and cellular fate transition, which contribute to the progression of disease. An understanding of the role of APs is necessary to develop effective intervention strategies, including potential molecular targets for clinical diagnosis and drug development, for inflammation-related diseases.


Assuntos
Fagócitos/citologia , Animais , Humanos , Fagócitos/metabolismo
6.
J Vasc Access ; 22(2): 292-298, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31808719

RESUMO

PURPOSE: The aim of this study is to evaluate the influence of arm movements from adduction to abduction on intracavitary electrocardiogram and the position of a catheter tip. METHODS: Overall, 192 peripherally inserted central catheter lines were placed under intracavitary electrocardiogram guidance and 188 of them were enrolled in the study. The catheter was first placed at a time point corresponding to the peak P wave with the arm in adduction. The arm was then abducted to 90° without changing catheter insertion length. During the procedure, basal electrocardiogram, intracavitary electrocardiogram, and radiographs with the arm in adduction and abduction were recorded. Amplitude wave changes and catheter movements were measured on electrocardiogram records and radiographs, respectively. RESULTS: In 188 cases, the P wave displayed typical changes, and 97.8% (184/188) catheters were successfully placed correctly. At the peak P wave, the amplitude of the peak P wave was 8.64 times greater than that of the basal P wave, and the P/R ratio was 0.61. When the arm was abducted to 90°, the amplitude of the P wave dropped to 57% of its peak, P/R decreased from 0.61 to 0.34, and the catheter tip moved cephalad 1.00 and 0.77 vertebral body units in male and female patients, respectively. CONCLUSION: Peripherally inserted central catheter moves toward the heart when the arm position changes from abduction to adduction. Peripherally inserted central catheter tip placement at the peak P wave with patient's arm in adduction is accurate and can prevent the catheter from advancing too low. R wave can function as a reference for observing P wave changes during peripherally inserted central catheter placement.


Assuntos
Braço/irrigação sanguínea , Cateterismo Venoso Central , Cateterismo Periférico , Eletrocardiografia , Posicionamento do Paciente , Postura , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Adulto Jovem
7.
Phlebology ; 35(8): 614-622, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32375605

RESUMO

BACKGROUND: The intracavitary electrocardiogram (IC-ECG) method has been used for the tip location of central venous access devices for the advantage of being safe, accurate and highly cost effective. However, long-term follow-up is rare. This randomized clinical trial aimed to evaluate the long-term complications of peripherally inserted central catheters (PICCs) positioned by the IC-ECG method. METHODS: We randomized 2250 patients who needed PICC placement to either a landmark length estimation supplemented by IC-ECG positioned group (ECG group) or the traditional landmark length estimation alone group (control group) in a 2:1 allocation. Post-procedural chest X-rays were applied to confirm tip position. Follow-up was performed monthly to six months. Standard statistics analyses were performed with the SAS 9.13 software, and p < 0.05 was considered significant. RESULTS: As evaluated by post-procedural chest X-ray, tip location in the ECG group had a first-attempt success (catheter tip located at optimal position) of 91.7% (95% confidence interval (CI): 90.3%-93.1%), significantly higher than 78.9% (95% CI: 76.0%-81.9%) observed in the control group (p < 0.001). At six-month follow-up, in the control group, frequency of total complications was 9.5%, including the exit site infection (4.0%), phlebitis (1.3%), deep venous thrombosis (1.5%), liquid extravasation (2.9%) and mechanical failure (1.9%). The IC-ECG group had significantly lower rates of complications (6.4%, p < 0.001), including the exit site infection (2.7%, p > 0.05), phlebitis (1.1%, p > 0.05), deep venous thrombosis (1.2%, p > 0.05), liquid extravasation (2.4%, p > 0.05) and mechanical failure (1.2%, p > 0.05). In the univariable logistic regression analysis, ECG method, other diseases and upper arms were the independent protective factors, and the number of adjustment procedures (n ≥ 2) were the independent risk factors of the complications. CONCLUSIONS: The intra-procedural tip location by IC-ECG is more safe and accurate than the traditional method of verifying tip location only post-procedurally, by chest X-ray.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Eletrocardiografia , Humanos , Radiografia
8.
Br J Neurosurg ; 34(4): 388-396, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32233810

RESUMO

Objective: Meta-analysis to evaluate complications in the use of autogenous bone and bone substitutes and to compare bone substitutes, specifically HA, polyetheretherketone (PEEK) and titanium materials.Methods: Search of PubMed, Cochrane, Embase and Google scholar to identify all citations from 2010 to 2019 reporting complications regarding materials used in cranioplasty.Results: 20 of 2266 articles met the inclusion criteria, including a total of 2913 patients. The odds of overall complication were significantly higher in the autogenous bone group (n = 214/644 procedures, 33.2%) than the bone substitute groups (n = 116/436 procedures, 26.7%, CI 1.29-2.35, p < 0.05). In bone substitutes groups, there was no significant difference in overall complication rate between HA and Ti (OR, 1.2; 95% CI, 0.47-3.14, p = 0.69). PEEK has lower overall complication rates (OR, 0.51; 95% CI, 0.30-0.87, p = 0.01) and lower implant exposure rates (OR, 0.17; 95% CI, 0.06-0.53, p = 0.002) than Ti, but there was no significant difference in infection rates and postoperative hematoma rates.Conclusions: Cranioplasty is associated with high overall complication rates with the use of autologous bone grafts compared with bone substitutes. PEEK has a relatively low overall complication rates in substitutes groups, but still high infection rates and postoperative hematoma rates. Thus, autologous bone grafts should only be used selectively, and prospective long-term studies are needed to further refine a better material in cranioplasty.


Assuntos
Procedimentos de Cirurgia Plástica , Crânio/cirurgia , Transplante Ósseo , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Próteses e Implantes/efeitos adversos
9.
Oncol Lett ; 19(4): 2870-2874, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32218841

RESUMO

Effect of gemcitabine (GEM) on proliferation and apoptosis of childhood acute leukemia (AL) cells and the mechanism of action were investigated. Bone marrow and peripheral blood of 18 newly diagnosed children with childhood AL admitted to Yidu Central Hospital of Weifang were selected, and the miR-125a-3p level in peripheral blood of healthy children and children with AL was detected by quantitative reverse transcription-polymerase chain reaction (qRT-PCR). Leukemia cells from the bone marrow of children with AL were primarily cultured and purified to observe the morphology. miR-125a-3p mimic was transfected into childhood AL cells. The cells were randomly divided into three groups: control group, GEM group and GEM + miR-125a-3p mimic group. 5-ethynyl-2'-deoxyuridine (EdU) staining assay was chosen to detect the proliferation of childhood AL cells in each group. Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining assay was adopted to determine apoptosis of childhood AL cells. The protein level of c-myc was measured via western blotting. Compared with that in the healthy children, the level of miR-125a-3p in the peripheral blood of children with AL was remarkably decreased. Compared with those in the control group, GEM inhibited proliferation and promoted apoptosis of childhood AL cells, and impeded the protein expression of c-myc in these cells. Compared with those in the GEM group, GEM + miR-125a-3p mimic notably reduced the proliferation and enhanced apoptosis of cells, and the protein expression of c-myc in cells was overtly reduced. The level of miR-125a-3p in peripheral blood of children with AL is obviously decreased. It is suggested in this study that GEM can inhibit the proliferation and promote apoptosis of childhood AL cells, and the mechanism may be related to upregulated miR-125a-3p inhibiting the expression of c-myc.

10.
Bioact Mater ; 5(2): 210-218, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32123774

RESUMO

Alloying combined with plastic deformation processing is widely used to improve mechanical properties of pure Zn. As-cast Zn and its alloys are brittle. Beside plastic deformation processing, no effective method has yet been found to eliminate the brittleness and even endow room temperature super-ductility. Second phase, induced by alloying, not only largely determines the ability of plastic deformation, but also influences strength, corrosion rate and cytotoxicity. Controlling second phase is important for designing biodegradable Zn alloys. In this review, knowledge related to second phases in biodegradable Zn alloys has been analyzed and summarized, including characteristics of binary phase diagrams, volume fraction of second phase in function of atomic percentage of an alloying element, and so on. Controversies about second phases in Zn-Li, Zn-Cu and Zn-Fe systems have been settled down, which benefits future studies. The effects of alloying elements and second phases on microstructure, strength, ductility, corrosion rate and cytotoxicity have been neatly summarized. Mg, Mn, Li, Cu and Ag are recommended as the major alloying elements, owing to their prominent beneficial effects on at least one of the above properties. In future, synergistic effects of these elements should be more thoroughly investigated. For other nutritional elements, such as Fe and Ca, refining second phase is a matter of vital concern.

11.
Coron Artery Dis ; 31(3): 199-205, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31833944

RESUMO

OBJECTIVE: We aimed to conduct a network meta-analysis of treatments for small vessels coronary artery disease between drug-eluting balloon (DEB) and drug-eluting stent (DES). METHOD: A meta-analysis comparing DEB and DES outcomes was performed using the Medline, Embase, and Cochrane databases. The primary outcome was target lesion revascularization (TLR) or target vessel revascularization (TVR), and myocardial infarction (MI), death and major adverse cardiovascular events (MACE) were secondary outcomes. A total of six studies on 1813 patients were included. RESULTS: There was no significant difference in rates of TLR or TVR in the patients treated with the DEB strategy compares with the DES strategy [odds ratio (OR) = 0.96, 95% confidence interval (CI) 0.57-1.61, P = 0.89] within a follow-up period of 9-24 months. There was a significant reduction in rates of MI and death in the patients treated with a DCB strategy compared with those treated with a DES strategy (3.7%, 17 of 460 vs 6.1%, 36 of 595; 2.4%, 11 of 460 vs 6.1%, 36 of 595, respectively), and this difference was statistically significant (OR = 0.53, 95% CI 0.29-0.96, P = 0.04; OR = 0.44, 95% CI 0.22-0.88, P = 0.02, respectively). There was no difference between DEB and DES strategies in rates of MACE (OR = 0.94, 95% CI 0.66-1.33, P = 0.73). CONCLUSION: In summary, this study demonstrates that treatment of small vessel (diameter ≤ 3 mm) coronary artery disease (CAD) with DEB may lead to improving outcomes compared with the use of DES within a follow-up period of 9-24 months. Further large clinical trials are needed to verify this conclusion.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Antineoplásicos/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Angioplastia Coronária com Balão/métodos , Humanos , Mortalidade , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Neointima/prevenção & controle , Metanálise em Rede
12.
Sci Rep ; 9(1): 18549, 2019 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811206

RESUMO

The Cordimax stent has proved non-inferior to the Cypher Select durable polymer sirolimus-eluting stent for the primary endpoint of angiographic in-stent late luminal loss and in-stent mean diameter stenosis at 9 months. The trial was designed to compare the efficacy and safety of the Cordimax stent with the Xience V stent in patients undergoing coronary revascularization. This randomized, multicenter trial enrolled 3697 patients treated with Cordimax stent (2460 patients) and Xience V stent (1237 patients). The primary efficacy endpoint was a target-lesion failure (TLF) at 1 year and the primary safety endpoint was a composite of death or myocardial infarction (MI) at 3 years. 3399 patients (91.9%) completed 3-year follow-up. At 1 year, the primary efficacy endpoint occurred in 86 (3.5%) patients in the Cordimax group versus 40 (3.2%) patients in the Xience V group (0.3% absolute risk difference, 95% CI -1.0-1.5%, Pnon-inferiority < 0.0001). At 3 years, the primary safety endpoint occurred in 39 (1.6%) patients in the Cordimax group versus 19 (1.5%) patients in the Xience V group (0.05% absolute risk difference, 95% CI -0.8-0.9%, Pnon-inferiority < 0.0001). The incidence of target lesion revascularization was low in Cordimax group compared with Xience V group (3.6% versus 5.1%, P = 0.03). There were no differences between Cordimax and Xience V in terms of Cardiac death (0.3% versus 0.4%, P = 0.70), myocardial infarction (1.2% versus 0.9%, P = 0.37), and the stent thrombosis (0.4% versus 0.6%, P = 0.61). In conclusion, safety and efficacy outcomes of Cordimax stent were non-inferior to the Xience V stent 3 years after stent implantation.


Assuntos
Estenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Implantes Absorvíveis/efeitos adversos , Assistência ao Convalescente , Idoso , Estenose Coronária/complicações , Estenose Coronária/mortalidade , Preparações de Ação Retardada/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Polímeros/química , Trombose/epidemiologia , Trombose/etiologia , Resultado do Tratamento
13.
Mater Sci Eng C Mater Biol Appl ; 104: 109896, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31499977

RESUMO

Zinc alloys have been explored as potential materials for biodegradable vascular stents due to their tolerable corrosion rates and tunable mechanical properties. However, the performances of Zn alloys were not supported with enough toxicity or biological compatibility evaluation, particularly hemocompatibility for vascular scaffolding application. In this work, the hemocompatibility of three zinc alloys (Zn-0.8Cu, Zn-0.8Mn and Zn-0.8Li) was evaluated with 316 L stainless steel and pure zinc as controls. The hemolysis ratios of 316 L stainless steel, pure Zn, Zn-0.8Cu, Zn-0.8Mn and Zn-0.8Li were 0.38 ±â€¯0.08%, 1.04 ±â€¯0.21%, 0.47 ±â€¯0.21%, 0.57 ±â€¯0.14% and 0.52 ±â€¯0.22%, respectively, for direct contact method. Platelets aggregation on the 316 L stainless steel was observed, while the adhered platelets on the Zn alloys exhibited round shape with few pseudopodia spreading. The number of adhered platelets on the three zinc alloys (Zn-0.8Cu, Zn-0.8Mn and Zn-0.8Li) had no statistically difference compared with 316 L stainless steel, while significant fewer than the pure Zn group. None remarkable platelet activation, hematocyte aggregation, coagulation or complement activation was observed in any Zn alloy group. Furthermore, the Zn alloys prolonged prothrombin time and partial thromboplastin time, demonstrating a potential function of anticoagulation. The results demonstrated that Zn alloys presented in this work are indeed meeting the hemocompatible requirements of implant and showing the promise for perspective application as biodegradable stent.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Lítio/química , Magnésio/química , Zinco/química , Implantes Absorvíveis , Ligas/administração & dosagem , Materiais Biocompatíveis/administração & dosagem , Coagulação Sanguínea/efeitos dos fármacos , Ativação do Complemento/efeitos dos fármacos , Corrosão , Hemólise/efeitos dos fármacos , Humanos , Lítio/administração & dosagem , Teste de Materiais/métodos , Ativação Plaquetária/efeitos dos fármacos , Aço Inoxidável/química , Stents , Zinco/administração & dosagem
14.
Acta Biomater ; 97: 657-670, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31401346

RESUMO

In the present study, a novel biodegradable Zn-0.8Cu coronary artery stent was fabricated and implanted into porcine coronary arteries for up to 24 months. Micro-CT analysis showed that the implanted stent was able to maintain structural integrity after 6 months, while its disintegration occurred after 9 months of implantation. After 24 months of implantation, approximately 28 ±â€¯13 vol% of the stent remained. Optical coherence tomography and histological analysis showed that the endothelialization process could be completed within the first month after implantation, and no inflammation responses or thrombosis formation was observed within 24 months. Cross-section analysis indicated that the subsequent degradation products had been removed in the abluminal direction, guaranteeing that the strut could be replaced by normal tissue without the risk of contaminating the circulatory system, causing neither thrombosis nor inflammation response. The present work demonstrates that the Zn-0.8Cu stent has provided sufficient structural supporting and exhibited an appropriate degradation rate during 24 months of implantation without degradation product accumulation, thrombosis, or inflammation response. The results indicate that the Zn-0.8Cu coronary artery stent is promising for further clinical applications. STATEMENT OF SIGNIFICANCE: Although Zn and its alloys have been considered to be potential candidates of biodegradable metals for vascular stent use, by far, no Zn-based stent with appropriate medical device performance has been reported because of the low mechanical properties of zinc. The present work presents promising results of a Zn-Cu biodegradable vascular stent in porcine coronary arteries. The Zn-Cu stent fabricated in this work demonstrated adequate medical device performance both in vitro and in vivo and degraded at a proper rate without safety problems induced. Furthermore, large animal models have more cardiovascular similarities as humans. Results of this study may provide further information of the Zn-based stents for translational medicine research.


Assuntos
Implantes Absorvíveis , Vasos Coronários , Teste de Materiais , Stents , Tomografia de Coerência Óptica , Animais , Cobre/química , Cobre/metabolismo , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Suínos , Fatores de Tempo , Zinco/química , Zinco/metabolismo
15.
J Cardiovasc Electrophysiol ; 30(9): 1671-1678, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31310416

RESUMO

BACKGROUND AND OBJECTIVES: The success rate of leadless cardiac pacemaker (LP) retrieval remains a major concern for this disruptive technology. The present paper performed a systematic review of the safety and feasibility of the retrieval of LPs. METHODS: Primary publications that performed LP retrieval were collected and included five animal experiments and two worldwide retrieval experiences in human. The procedural details, such as indication, days post implantation, extraction success rate, and complications, were described. The present paper analyzed factors affecting the retrieval and management of the nonfunctional devices. RESULTS: Retrieval animal models was possible at least up to 2.5 years post implantation, and data from humans suggest that removal of a device that was implanted longer (eg, 4 years and 9 months for Nanostim; 4 years for Micra) could be performed within a reasonable safety profile. The fixed mechanism, implant site, and encapsulation of the LP systems may affect the retrieval process. CONCLUSIONS: A high success rate in the relatively chronic retrieval of LPs was demonstrated, which promotes the extensive use of these devices in the treatment arrhythmia in the future.


Assuntos
Estimulação Cardíaca Artificial , Remoção de Dispositivo/métodos , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Animais , Remoção de Dispositivo/efeitos adversos , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Front Psychol ; 10: 1308, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31214096

RESUMO

By manipulating the location of prosodic boundary and the semantic bias of the ambiguous "V+N1+de+N2" phrase, which is composed of one verb (V), one noun (N1), one functional word (de), and another noun (N2), this study investigated how prosodic boundary and the semantic bias affect the processing of temporary ambiguous sentences formed by the ambiguous phrase "V+N1+de+N2" through an eye movement experiment. We found the effect of prosodic boundary in the late processing stage and observed an interaction between prosodic boundary and the semantic bias of ambiguous phrases as well. The participants required more time for fixation and more regressions occurred when the meaning of the ambiguous phrase guided by prosodic boundary was inconsistent with context, especially when the ambiguous phrase was biased to the narrative-object phrase. This result suggests that prosodic boundary affects the processing of temporal ambiguous sentences and is influenced by the semantic bias of the ambiguous phrase. These findings provide further evidence from Chinese that indicate that implicit prosody plays a general role in language comprehension.

17.
Mater Sci Eng C Mater Biol Appl ; 99: 969-978, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30889772

RESUMO

Zn-0.8Mn (in wt%) alloy with good ductility is used for design of novel Zn-0.8Mn-0.4x (x = Ag, Cu or Ca) alloys. Hot extrusion not only eliminates brittleness of the as-cast alloys but also significantly improves their strengths. Among them, Zn-0.8Mn-0.4Ca exhibits the highest strength, Zn-0.8Mn-0.4Ag exhibits the highest ductility, but Zn-0.8Mn-0.4Cu exhibits the best combination of strength and ductility. The minor addition of Ag, Cu or Ca accelerates alloy degradation in simulated body fluid. However, Cu addition much improves in vitro biocompatibility and endows antibacterial ability of Escherichia coli. Overall, Zn-0.8Mn-0.4Cu alloy has the best comprehensive properties.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Cálcio/química , Cobre/química , Prata/química , Animais , Antibacterianos/farmacologia , Linhagem Celular , Sobrevivência Celular , Corrosão , Espectroscopia Dielétrica , Escherichia coli/efeitos dos fármacos , Camundongos , Testes de Sensibilidade Microbiana , Resistência à Tração
18.
J Vasc Access ; 20(6): 577-582, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30838913

RESUMO

BACKGROUND: Recently, intracavitary electrocardiogram technology has been applied to peripherally inserted central catheter placement and demonstrates many potential advantages. However, the tip positioning accuracy of intracavitary electrocardiogram technology compared to conventional X-ray method is unknown. OBJECTIVE: We did a meta-analysis to compare the tip positioning accuracy between intracavitary electrocardiogram technology and conventional X-ray method. DATA SOURCES: We searched several databases, including Cochrane Library, PubMed, Web of science, and Embase. Additional studies were identified through hand searches of bibliographies and Internet searches. All human studies published in full text, abstract, or poster form were eligible for inclusion. Search terms included peripherally inserted central catheter, PICC, intracavitary electrocardiogram, IC-ECG, EKG, ECG, and catheter tip location. STUDY ELIGIBILITY CRITERIA: Only randomized controlled trials of using intracavitary electrocardiogram technology versus X-ray method for peripherally inserted central catheter placement were included. All studies included adult patients aged at least 18 years. STUDY APPRAISAL AND SYNTHESIS METHODS: Independent extraction of articles by two authors using predefined data fields, including study quality indicators. Of the 178 citations identified, 5 studies that included 1672 patients met the eligibility criteria. It was found that statistical heterogeneity existed among the various studies (I2 = 16%, p < 0.00001); therefore, the fixed effect model was used in the meta-analysis (p < 0.05). The meta-analysis compared the tip positioning accuracy between intracavitary electrocardiogram technology and X-ray method and showed that intracavitary electrocardiogram technology had a better positioning accuracy (odds ratio: 2.88, 95% confidence interval: 2.15-3.87, p < 0.0001). LIMITATIONS: Only five randomized trial met inclusion criteria, and the lack of an incomplete search led to the publication bias seen in these results. CONCLUSION: The intracavitary electrocardiogram method had a more favorable positioning accuracy versus traditional X-ray method for peripherally inserted central catheter placement in adult patients. The intracavitary electrocardiogram can be a promising technique to guide tip positioning of peripherally inserted central catheter.


Assuntos
Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Eletrocardiografia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Cateteres Venosos Centrais , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Radiografia Intervencionista , Ensaios Clínicos Controlados Aleatórios como Assunto
19.
J Cardiovasc Pharmacol ; 73(4): 241-247, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30688797

RESUMO

BACKGROUND: Radiofrequency ablation (RFA) and antiarrhythmic drugs (AADs) are the main treatments used for atrial fibrillation (AF). In recent years, a number of articles comparing the 2 treatments have begun to emerge. Though, the influence of follow-up time in the meta-analysis was not considered in these articles. However, more recently, large-scale clinical trial articles have included follow-up with the patients up to 5 years after treatment. Therefore, the aim of this study was to assess the impact of variable follow-up times on the recurrence of AF by observing both the short-term and long-term efficacy and safety of catheter ablation and AADs for the treatment of AF. METHODS AND RESULTS: The primary investigators of eligible randomized controlled trials were invited to contribute standardized outcome data. Random effect summary estimates were calculated as standardized mean differences and odds ratios with 95% confidence intervals for continuous and binary outcomes. In this study, 9 randomized controlled trials (n = 1542 patients) were included. The rate of recurrence of AF with no limit on follow-up time, >12 months, >18 months, >24 months, >30 months, and approximately 36 months was compared. Furthermore, the gap between the RFA and AAD groups in the recurrence rate of AF was found to decrease inversely to follow-up time. When the follow-up time reached 24 months, the difference between RFA and AAD was relatively stable with an odds ratio of 0.45 (95% confidence interval: 0.32-0.62). Overall, RFA decreased adverse events in the remaining trials; however, AAD performed better in terms of safety and had fewer adverse events with RFA usually causing more serious complications. CONCLUSION: RFA is more advantageous in terms of recurrence rate of AF than drug therapy. In addition, the analysis suggests that this effect persists during long-term follow-up; however, these benefits appear to decrease with longer follow-up time. Finally, AAD performed better in terms of safety and had fewer adverse events.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter , Frequência Cardíaca/efeitos dos fármacos , Potenciais de Ação , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Vasc Access ; 20(5): 524-529, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30596472

RESUMO

INTRODUCTION: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device. METHODS: Our study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip. RESULTS: No insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%-93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%-81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity of 99.3% (95% confidence interval: 98.8%-99.7%), significantly higher than 86.8% (95% confidence interval: 84.4%-89.2%) observed in the anatomical landmark group (p < 0.001). CONCLUSION: These results indicated that during peripherally inserted central catheters insertion in adult patients, tip location with intracavitary electrocardiogram guidance, as carried out by a new tip-conductive peripherally inserted central catheters and intracavitary electrocardiogram integrated ultrasound device, was more effective and more accurate than tip location using anatomical landmarks.


Assuntos
Cateterismo Periférico/instrumentação , Cateteres de Demora , Pressão Venosa Central , Eletrocardiografia/instrumentação , Transdutores , Ultrassonografia Doppler/instrumentação , Ultrassonografia de Intervenção/instrumentação , Idoso , Pontos de Referência Anatômicos , Cateterismo Periférico/efeitos adversos , China , Eletrocardiografia/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...